600 kVA Stage V Generator

Robust and fuel efficient, our Stage V generators can deliver on your temporary power needs without sacrificing performance. Installed and monitored by experts, our Stage V generators deliver low-emission energy generation through improved technology.

Our 600 kVA Stage V generator offers greater efficiencies, low noise levels, and lessens the impact on global and local emissions - and can run on both diesel and HVO.

Data is based on 50 Hz. For more information please request a data sheet or download our Stage V generator brochure.

600 kVA Stage V Generator

600 kVA Stage V Generator

Robust and fuel efficient, our Stage V generators can deliver on your temporary power needs without sacrificing performance. Installed and monitored by experts, our Stage V generators deliver low-emission energy generation through improved technology.

Our 600 kVA Stage V generator offers greater efficiencies, low noise levels, and lessens the impact on global and local emissions - and can run on both diesel and HVO.

Data is based on 50 Hz. For more information please request a data sheet or download our Stage V generator brochure.

CO (Carbon Monoxide)

50 Hz - 0.043 g/kWhr

CO (Carbon Monoxide)

60 Hz - 0.066 g/kWhr

HC (Unburnt Hydrocarbons)

50 Hz - 0.007 g/kWhr

HC (Unburnt Hydrocarbons)

60 Hz - 0.013 g/kWhr

NOx (Oxides of Nitrogen)

50 Hz - 0.17 g/kWhr

NOx (Oxides of Nitrogen)

60 Hz - 0.4 g/kWhr

PM (Particulate Matter)

50 Hz - 0.012 g/kWhr

PM (Particulate Matter)

60 Hz - 0.0137 g/kWhr

100% prime power

50 Hz - 113.1 l/hr

100% prime power

60 Hz - 141.2 l/hr

50% prime power

60 Hz - 73.5 l/hr

75% prime power

50 Hz - 84.9 l/hr

50% prime power

50 Hz - 66.4 l/hr

75% prime power

60 Hz - 106.5 l/hr

Sound Power EEC

100

Sound Pressure at 1M

50 Hz - 81.5 dBA

Sound Pressure at 1M

60 Hz - 81.6 dBA

Sound Pressure at 7M

50 Hz - 73.1 dBA

Sound Pressure at 7M

60 Hz - 72.4 dBA

Height (m)

2.9m

Length (m)

5.16m

Weight (kg.) Without Fuel

8782

kg

Width (m)

1.9m

Features
  • Designed and assembled to Aggreko’s standards
  • Bolted, galvanised, alloy steel canopy with lockable doors
  • Acoustically designed equipment
  • Low fuel level warning sensor in fuel tank
  • Forklift pockets in base frame and lifting beam on top
  • Optional 2-point lifting arrangement
Benefits
  • Reduced emissions and compliant with the latest EU Stage V regulations
  • New aftertreatment system making it more efficient than the previous generation of diesel engines
  • Flexible 50 and 60 Hz units
  • Data driven, which allows better remote information – smarter servicing
  • Works perfectly on alternative fuels as HVO
  • Arc Flash detection and ingress protection moisture louvres, giving better protection of the internal components of the canopy from the environment
  • Range of warnings and shutdowns on control system protects generator set from electrical and mechanical damage, helps identify and rectify faults before they occur
+50 years developing temporary projects all over the world

Related projects

Aquaculture

Generator powers up a fish farm

Construction

Drying out a construction site

Petrochemical and refining

Powering Up During Maintenance
Experts in energy transition

Have a look at our solutions

Remote monitoring

Stay one step ahead

Disaster Recovery

Emergency response Solutions
Every year, we help businesses and governments bounce back quickly after floods, or fires, threaten operations.